 RADIO REMOTE CONTROL SYSTEMS
FIREFLY FIREBLADE
Applications Features
* 1,2,4 or 8 Channel Systems * 12 / 24Vdc or 230Vac Supply * Range
FireFly up to 100 metres FireBlade up to 1,000 metres * Reliable FM Technology
* * * *
Lighting Control General Purpose Remote Switching Industrial remote Switching Access Control
Description
A Range of general purpose remote control systems Installation simply requires connections to power supply and the output relay screw terminals. The output relays are activated by the button press on the transmitter encoder. Housed in a rugged IP68 weatherproof enclosure, the receiver has the capacity to learn up to 15 transmitter button pairings. These are memorised even if the power is removed. Each individual switch on each of the transmitters may be paired with any or all of the receiver relay outputs. The decoder is supplied in an IP68 rated enclosure with Cable Gland and wall mounting lugs.
* * * * * * * * *
High Security RF Protocol `Easy Learn' Tx Encoder Feature Easy Installation Via Screw Terminals. 4 Relays 6A @ 230Vac Momentary / Latch / Timed Outputs Timed Output Adjustable 0 To 5 mins Any Switch `Maps to Any Relay Output Receiver Rated IP68 Versatile operation modes: Many to Many, One to Many, Many to One.
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
Page 1
RADIO REMOTE CONTROL SYSTEMS
FireFly Systems LOS Range 100m
FIREFLY FIREBLADE
Part Number FIREFLY-S1 FIREFLY-S2 FIREFLY-S4
Description FM RC System 1 ch FM RC System 2 ch FM RC System 4 ch
Freq (MHz) 433.92 433.92 433.92
Range** (Metres) 100 100 100
Additional FireFly Transmitters Part Number FIREFLY-TX1 FIREFLY-TX2 FIREFLY-TX4 FIREFLY-TX8 FIREFLY-TX-IPKIT Description Transmitter 1 switch Transmitter 2 switch Transmitter 4 switch Transmitter 8 switch Freq (MHz) 433.92 433.92 433.92 433.92 Range** (Metres) 100 100 100 100
Belt Clip and 'O' Ring, Seals Transmitter to IP67
FireBlade Systems LOS Range 1,000m
Part Number FIREBLADE-S1 FIREBLADE-S2 FIREBLADE-S4 Additional FireBlade Transmitters Part Number FIREBLADE-TX1 FIREBLADE-TX2 FIREBLADE-TX4 FIREBLADE-TX8 FIREFLY-TX-IPKIT
Description FM RC System 1 ch FM RC System 2 ch FM RC System 4 ch
Freq (MHz) 434.525 434.525 434.525
Range** (Metres) 1,000 1,000 1,000
Description Transmitter 1 switch Transmitter 2 switch Transmitter 4 switch Transmitter 8 switch
Freq (MHz) 434.525 434.525 434.525 434.525
Range** (Metres) 1,000 1,000 1,000 1,000
Belt Clip and 'O' Ring, Seals Transmitter to IP67
** Range stated is optimum, direct line of sight. In worst conditions this can be reduced significantly.
Custom Options
These systems may be supplied as OEM units. Both transmitter and receiver use overlay stickers as part of the assembly which may easily be customised to incorporate any other logo etc. Please contact our sales dept for further information.
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
Page 2
RADIO REMOTE CONTROL SYSTEMS
Power Supply
FIREFLY FIREBLADE
This unit is designed to be a fixed installation, operated from either 12/24Vdc or 230Vac. Under no circumstances should the receiver be connected to more than one supply. Before removing the cover ensure that the mains input supply is isolated. Maintenance to the product that involves removal of the cover should only be carried out by a competent person or qualified electrician.
Data Outputs
Each output relay provides an isolated switch. Connections are Common (COM), Normally Open (NO) and Normally Closed (NC).
Relay Connections when Transmitter NOT Operating
Connecting a Relay output to an Application
Below is a simple example showing one possible way to wire a relay in order to give switched power to an external load:
When the relay is energised the `COM' connects to 'NO' and power is applied to the Load.
Pairing a Transmitter to a Receiver
Each transmitter has a unique identity. Each time a switch is pressed, the transmitter emits a highly secure RF signal (appears as a random encrypted data stream). The Receiver can learn this encrypted signal and allocate to an output. Any transmitter switch may be paired to one or many of the receiver's outputs, or a transmitter single switch may be paired to any number of receiver's outputs to enable a powerful and flexible remote control system. The only limitation is that each receiver has a maximum capacity of 15 pairings, these can be from the same or any number of transmitters. Hint: the same transmitter may be taught to any number of receivers to create `master keys'.
NC COM NO
Relay Connections when Transmitter OPERATING
NC COM NO
105 RECEIVER UNIT
N.C.
0V+12V
RELAY OUTPUT 1
COM N.O.
0V
+12V
LOAD 0V +12V
SUPPLY
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
Page 3
RADIO REMOTE CONTROL SYSTEMS
To learn a new transmitter switch follow this procedure
Any transmitter button can be learnt to one or many of the receiver output relays. Each button must be learnt to each relay individually by following this procedure: 1.
FIREFLY FIREBLADE
2. 3. 4. 5.
To select the receiver output relay to learn to: a. Briefly press the receiver Learn switch (SW1) once b. The Learn LED will flash once to indicate output relay 1 is selected c. After the LED stops flashing, press the Learn switch again to select the next relay channel d. Repeat step c until the required output relay is selected. Press the button on the transmitter you want to learn to the relay output. The Learn LED will then illuminate, press the same transmitter button again. The Learn LED will then flash to indicate learning is complete. To test the operation, press the transmitter button again and you will hear the relay `click' as it operates.
Erasing Receivers Memory
1. Press and hold the receiver Learn Switch for approx 10 seconds. 2. When the Learn LED turns OFF all memory is erased 3. This is factory default state which is indicated by all output LED's flashing together. NOTE: You cannot erase individual Tx encoders
Receiver Outputs
The jumper links configure the outputs to be Momentary, Latching or Timed. The jumper links are made / removed by a small link `cap' placed over the pin header. Jumper Links (LK2 - 4) Open Connected Outputs 2 - 4 Mom (The Output operates for as long as the transmitter switch is held on) Latch (The Output changes state each time the Transmitter is operated)
LK0 Open Open Connected Connected
LK1 Open Connected Open Connected
Relay Outputs Output 1 Momentary Output 1 Latching All Outputs fixed to 1/2 Second Momentary o/p Output 1, 0 to 5 minutes using Timer selection Potentiometer. Page 4
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
RADIO REMOTE CONTROL SYSTEMS
Technical Specifications
Transmitters : FireFly, FireBlade Enclosure Rating: Standard IP40 (TBC) With IPKit IP65 (TBC) Battery Type: CR2032 (supplied) Dimensions: 90 x 54 x 27 mm (Note: FireBlade is supplied with external Antenna)
Electrical Characteristics Supply Voltage Supply Current Frequency: FireFLY: Wideband FireBLADE: Narrowband RF Output Power (ERP) @ 433 MHz Min Typical 3V 433.920 434.525 3 Max
FIREFLY FIREBLADE
Units
V mA
432.90 434.450 -
434.10 434.600 10
MHz mW
Receiver Decoder Enclosure Rating Dimensions Storage Temperature: Operating Temperature:
IP68 169 x 132 x 85mm (not including antenna) o -10 to +70 Celsius. o 0 to +55 Celsius.
ELECTRICAL CHARACTERISTICS MIN TYPICAL MAX DIMENSION Supply Voltage for +12 v 10 12.0 16 Vdc Supply Voltage for +24 v 22 24.0 28 Vdc Supply Voltage for 230Vac 230 Vac Relay Rating* (230Vac) RLY1-4 5 12 A Supply Current : Quiescent 16 All relays operating* 140 mA Time delay from Tx on Switch to Rx Relay operation 100 mS Time delay from Tx sw relax to Rx Relay release 300 MS *The relay contacts in this unit are for functional use only and must not be used for isolation purposes
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
Page 5
RADIO REMOTE CONTROL SYSTEMS
Receiver Mechanical Dimensions
FIREFLY FIREBLADE
R F Solutions Ltd., Unit 21, Cliffe Industrial Estate, Lewes, E. Sussex. BN8 6JL. England.
Email : sales@rfsolutions.co.uk
Tel: +44 (0)1273 898 000
http://www.rfsolutions.co.uk
Fax: +44 (0)1273 480 661
Information contained in this document is believed to be accurate, however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd.
DSFIREFLY-3
March 08
(c)2008 REG No 277 4001, ENGLAND.
Page 6


▲Up To Search▲   

 
Price & Availability of FIREBLADE-S1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X